New product launch: Taiwan JK Jiqi broken line detector

Product Name: Taiwan JK product odd line detection device

Product Model:JK022VBC

I. Product Description

The disconnection detector provides the equipment to check whether the load is disconnected all the time, so that the equipment maintains the best condition. It will not be because of the equipment condition to repair the line and time-consuming, the finished product yield is reduced, and 12-stage load inspection is provided. The anomaly notification contact allows the customer to install a beeper or warning light on their own. Once the load is disconnected, the operator is notified immediately, eliminating the time required to repair the circuit, and the 12 LED indicators will change the load according to the lighted LED. It is suitable for load detection of three-phase SCR power regulators, three-phase SSR solid-state relays, single-phase SCR power regulators, and single-phase SSR solid state relays.

II. Function description

1. Make 12-segment LED inspection when powering on. When 12 LEDs light up once through the marquee mode, it means that 12 LEDs are all fault-free and standby is normal.

2. Provide 12-stage load disconnection detection, 1-12 segments can be freely selected and matched, for example, select 2 or 6 segments for load detection. If there is no used part, turning off the DIP switch will not start the inspection. Knowledge function. Provide multiple segments of the dial switch to start and close the disconnection detection function, more in line with the different use of the environment.

3. External LED indicator, can be extended 1-2m through the connection of the cable, 12 LED indicator functions on the synchronous control board, can be connected to the obvious place of the device via the cable, such as the control box surface, the operation of the device The panel allows the operator to know the status of the equipment instantly.

4. Provide two kinds of machine choices; Detect SCR power regulator, detect SSR solid state relay.

5. Determine whether the load is disconnected by confirming the CT flowmeter and the thermometer.

Three. Specification

1. Auxiliary voltage: AC 220V ±15% 50/60Hz

2. Operating frequency: 50-60Hz ±5%

3. Model selection: Detect SCR power regulator and detect SSR solid state relay. (Please also inform the business when ordering)

4, the use of the environment: -10 degrees -50 degrees humidity below 90% RH

5, with the thermometer receiving signal: 4-20mA, 0-5V, 1-5V

6, with SSR thermometer: NO-OFF