Precautions for using biochemical incubator

Intelligent Biochemical Incubator.jpg

Shanghai Haozhuang Instrument Co., Ltd. Haozhuang (LNB) brand biochemical incubator is a two-way temperature regulation system with refrigeration and heating, temperature controllable function, is biological, genetic engineering, medicine, health and epidemic prevention, environmental protection, agriculture, forestry, animal husbandry, etc. The important test equipment of the industry's scientific research institutions, universities, production units or departmental laboratories, and biochemical incubators are widely used in low temperature and constant temperature tests, cultivation tests, and environmental tests. The controller circuit of the biochemical incubator is composed of a temperature sensor, a voltage comparator and a control execution circuit.

Matters needing attention when using biochemical incubator:

1. The biochemical incubator should be installed in a place where the temperature and humidity change is as small as possible. Use a three-pin plug? The socket should be properly grounded.

2. Before starting the biochemical incubator, you should be fully familiar with and understand the instructions of each supporting instrument and instrument, and master the correct use method.

3. It is strictly forbidden to contain volatile chemical solvents? Explosive and flammable gases are placed in the box. Do not use flammable sprays near the incubator to avoid spark ignition.

4. Regularly check the air circuit for leaks.

5. The biochemical incubator has a power-off protection function, so it will take about one and a half minutes to restart the compressor after it is stopped, so as to better protect the compressor.

6. The distance between the condenser and the wall of the biochemical incubator should be greater than 100mm, the side of the box should have a gap of 50mm, and the top of the box should have at least 300mm space to ensure good heat dissipation.

7. When carrying, repairing and maintaining the biochemical incubator, avoid collision and shaking, and the maximum inclination should be less than 45 degrees.

8. When you stop using for a long time, you should turn off the main power and the power switch at the rear of the device. ? At the same time, the biochemical incubator should avoid frequent opening of the door to maintain stable temperature, and at the same time prevent dust and dirt from entering the working room.

9. The inside and outside of the box should be kept clean every day, and should be cleaned after each use. If it is not used for a long time, it is necessary to wipe the tank liner and equipment surface frequently to keep it clean and increase the transparency of the glass. Do not wipe the outer surface with acid, alkali or other corrosive solutions.

10. Turn off the power switch after cultivating. Do not open the door of the box unless the experimental samples are taken out immediately.

11. The biochemical incubator should not be used in abnormal environments such as high voltage, large current, and strong magnetic field, and strictly follow the electrical safety operation rules.

The Haozhuang (LNB) brand biochemical incubator of Haihaozhuang Instrument Co., Ltd. makes the experiment more stable, easier to operate, and more efficient. It mainly promotes the SPX series biochemical incubator. The biochemical incubator sold by Shanghai Haozhuang Instrument has a reasonable price and stable function. Welcome new and old customers to consult and buy!