Instructions for human protein tyrosine phosphatase antibody (IA-2A) elisa kit

Human protein tyrosine phosphatase antibody (IA-2A) elisa kit instructions ELISA kit instructions for use This kit is for research use only. Detection range: 96T50U / L-1600U / L Purpose: This kit is used to determine the content of protein tyrosine phosphatase antibody (IA-2A) in human serum, plasma and related liquid samples. Experimental principle The kit uses the double antigen sandwich method to determine the level of human protein tyrosine phosphatase antibody (IA-2A) in the specimen. A microplate was coated with purified human protein tyrosine phosphatase antigen to prepare a solid-phase antigen. Protein tyrosine phosphatase antibody (IA-2A) was added to the microwells coated with mAb in turn, and then labeled with HRP The protein tyrosine phosphatase antigen binds to form an antigen-antibody-enzyme-labeled antigen complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the protein tyrosine phosphatase antibody (IA-2A) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human protein tyrosine phosphatase antibody (IA-2A) in the sample was calculated by a standard curve. Kit composition 1 30 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle 2 enzyme label reagent 6ml × 1 bottle 8 standard (3200U / L) 0.5ml × 1 bottle 3 enzyme label coated plate 12 well × 8 strips 9 standard diluent 1.5ml × 1 bottle 4 sample diluent 6ml × 1 bottle 10 instruction manual 1 copy 5 developer A solution 6ml × 1 bottle 11 sealing film 2 sheets 6 developer B solution 6ml × 1 / Bottle 12 sealed bag 1 specimen requirement 1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity. Procedure 1. Dilution of standard product: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart. 1600U / L No. 5 standard 150μl original standard add 150μl standard dilution 800U / L No. 4 standard 150μl standard No. 5 add 150μl standard dilution 400U / L No. 3 standard 150μl No. 4 standard Add 150μl standard dilution 200U / L No. 2 standard 150μl No. 3 standard add 150μl standard dilution 100U / L No. 1 standard 150μl No. 2 standard add 150μl standard dilution 2. Add sample: Separately set blank wells (the blank control wells do not add samples and enzyme label reagents, the rest of the operation is the same), standard wells, sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix. 3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes. 4. Mixing solution: Dilute 30 times concentrated washing solution with distilled water 30 times and reserve for use 5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with washing solution, let it stand for 30 seconds and then discard , Repeat this 5 times, pat dry. 6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well. 7. Incubation: The operation is the same as 3. 8. Washing: The operation is the same as 5. 9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop color at 37 ° C in the dark 15 minutes. 10. Stop: add 50μl of stop solution to each well to stop the reaction (at this time, the blue will turn to yellow). 11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution. Human protein tyrosine phosphatase antibody (IA-2A) elisa kit instruction manual operation procedure summary: calculation takes the concentration of the standard as the abscissa, the OD value is the ordinate, draw a standard curve on the coordinate paper, according to the OD of the sample The corresponding concentration is found by the standard curve; multiplied by the dilution factor; or the linear regression equation of the standard curve is calculated from the concentration of the standard and the OD value, and the OD value of the sample is substituted into the equation to calculate the sample concentration, and then multiplied by The dilution factor is the actual concentration of the sample. Matters needing attention 1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag. 2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing. 3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples. 4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple (n times) of the sample diluent and then determine it. Please multiply the total dilution for the calculation Multiple (× n × 5). 5. The sealing film is limited to one-time use to avoid cross-contamination. 6. Please keep the substrate away from light. 7. Strictly follow the instructions, and the test results must be determined based on the reading of the microplate reader. 8. All samples, washing liquids and various wastes should be treated as infectious agents. 9. The components of different batches of this reagent shall not be mixed. 10. If there is any difference with the English manual, the English manual shall prevail. Storage conditions and validity period Kit storage :; 2-8 ℃. 2. Validity: 6 months manual of human protein tyrosine phosphatase antibody (IA-2A) elisa kit

Stainless steel/Melamine Pet Bowl make clean easily and your lovely dog can bit it freely. Cute Pet Bowl can be used for water feeding and food feeding, it's easy for storage and transportation. This dog/cat feeder bowl can stumulate your pet's appetite for more healthy growth.

Melamine Pet Bowl made of food grade melamine material that are BPA, PVC and phthalate free, scratch-resistant and high gloss(which can't be seen in other plastic bowls), acid and alkali corrosion resistance, dishwasher safeIn comparison to other materials such as ABS material and plastic, melamine material is more heavy for the size to reduce tipping over, rubberized bottom reduces skid.

Pet Bowl

Stainless Steel Dog Bowl,Melamine Bowl,Stainless Steel Full Color Bowl,Stainless Steel Cat Bowl

Homefelt Houseware co.,ltd , https://www.dghomefelt.com